The Eye Movement Recording system with
automatic Reading analysis.
In a few minutes, the
Readalyzer™ objectively measures reading
skill.
A Readalyzer measurement is fast and easy. The subject puts the
measuring goggles on. If the subject has ordinary glasses or contact
lenses, they can be worn as usual with the recording goggles being
worn over them. The interpupillary distance is
adjusted, and the subject reads a text from the text booklet. The
system auto-calibrates in seconds and the patient is free to move as
they would naturally. The primary use of the Readalyzer is to
analyze the mechanics of eye movements used during reading.
The Readalyzer is supplied with a series of graded stories with
comprehension tests to assure that the reading sample taken is a
valid measure of the person's true reading ability. The
Readalyzer has multiple language support as well as a series of
special 800+ word long stories. The long stories give more
insight into prolonged reading performance that is essential in
gaining insight into the person's reading abilities.
Objective data that is obtained with the Readalyzer includes the
number of fixations and regressions per 100 words read, the average
duration of fixation, reading speed, and comprehension. The
device is powered by the USB connection. The goggles afford
the most open field of view of the devices commonly used by
optometry.
The analysis gives the following values:
-
Fixations
-
Regressions
(backward movements during reading)
-
Fixation
duration (mean, standard deviation and as histogram)
-
Reading speed
-
Cross
Correlation between right and left eye
-
Play-Back of
recorded Eye Movements on top of text read
The recorded eye movements can
be shown
superimposed on the text read. A
black rectangle
shows the fixation area in the
text. This is very
useful to explain the reading
process to the
tested person.
You can also view the recording
as a graph where the text is synchronized with the eye movements and
details
about the analysis are shown. The Readalyzer system can be
used to:
-
Evaluate reading skill
-
Monitor individual reading
skill development
-
Check that reading skill
goals have been achieved
-
Objectively measure reading
parameters such as reading
speed, regressions and fixation duration
Technical information: The Readalyzer system consists
of a measuring unit, measuring goggles, a book of stories and
software.
The system is powered through the USB connection. Power consumption
is 100 mA. The system can
easily be run from a battery operated laptop computer. The
power consumption of the Readalyzer
system is negligible compared to the computer and will only
marginally reduce running time on the battery.
Computer requirements:
-
CPU: Pentium-class or
better.
-
Connection: USB 1.1 or
better.
-
Operating system: Windows
with USB support. (Windows 95B or higher including Vista)
-
Space on hard drive: 10
Megabytes for program + approx. 10 kilobyte for each measurement.
Additional Information |
Download the "Getting Started" Booklet - written by Paul
Harris (PDF) |
Download the technical manual - written by Kurt Mirdell -
the system developer (PDF) |
Listen to an audio of Paul Harris explaining the reasons for
the varying print sizes in some of the stories (WMA
- Windows Media Audio Player file) |
Go to the OEP
On-Line Store to Purchase |

The
OEP is dedicated to providing information on vision.
Optometric
Extension Program Foundation
1921 E. Carnegie Ave., Suite 3-L, Santa Ana, California, USA, 92705-5510
Telephone: 949-250-8070 FAX: 949-250-8157
Copyright ©
OEP,
all rights reserved
|
|
|